Product Description
1. Instant Parameter Displaying: set temp, air temp, heat
power rate;
2. Audible & Visual Alarms: power failure, sensor failure,
higher/lower temp, air temperature override, fan failure;
3. Power failure reset memory and self-test function;
4. Hood with dual slope: 4 hand-ports.
| ROC01-B803 | ROC01-B802 | ROC01-B801 | ROC01-B800 |
Mattress to Hood | 450mm | 450mm | 450mm | 410mm |
Observation side of hood | Two incline | Two incline | Two incline | Two incline |
Operate port | 6 | 6 | 6 | 4 |
Front access panel | 826*310mm | 826*310mm | 826*310mm | 826*280mm |
Mattress tray size | 630*360mm | 630*360mm | 630*360mm | 630*360mm |
Power supply | ≤400VA | ≤400VA | ≤400VA | ≤400VA |
Temperature controlled by microcomputer | Air and skin temp Air temp | Air and skin temp Air temp | Air temp | Air temp |
Air temp control range | 20oC-37oC | 20oC-37oC | 20oC-37oC | 20oC-37oC |
| 37oC-39oC | 37oC-39oC | 37oC-39oC | -------- |
Skin Temp control range | 30oC-37oC | 30oC-37oC | ----------- | ------------ |
| 37oC-38oC | 37oC-38oC | ------------ | ------- |
Skin Temp sensor accuracy | ≤0.3oC | ≤0.3oC | ------------ | ------- |
Humidity display range | 5%-99% | ------------- | --------- | -------------- |
Temperature fluctuation | ≤0.5oC | ≤0.5oC | ≤0.5oC | ≤0.5oC |
Mattress temperature uniformity | ≤0.8oC | ≤0.8oC | ≤0.8oC | ≤0.8oC |
Temperature rise time | ≤30min | ≤30min | ≤30min | ≤30min |
Noise level within hood environment | ≤55dB | ≤55dB | ≤55dB | ≤55dB |
Alarms |
|
|
|
|
Power failure alarm | yes | Yes | yes | yes |
Fan failure alarm | yes | Yes | yes | yes |
Sensor failure alarm | yes | Yes | yes | yes |
High air temp alarm | +1.5oC | +1.5oC | +1.5oC | +1.5oC |
Low air tem alarm | -2.5oC | -2.5oC | -2.5oC | -2.5oC |
High skin temp alarm | +1.0oC | +1.0oC | ---- | --- |
Low skin tem alarm | -1.0oC | -1.0oC | ----- |
|
Over air tem alarm | ≤38oC, ≤40oC | ≤38oC, ≤40oC | ≤38oC, ≤40oC | ≤38oC |
Over skin tem alarm | ≤38oC, ≤39oC | ≤38oC, ≤39oC | ≤38oC, ≤39oC | -- |
System failure alarm | yes | yes | yes | -- |
Alarm silence function | yes | yes | yes | --- |
Operational condition |
|
|
|
|
Environment temperature | +20oC-+30oC | +20oC-+30oC | +20oC-+30oC | +20oC-+30oC |
Environment relative humidity | 5%-99% | 5%-99% | 5%-99% | 5%-99% |
Environment air velocity of flow | <0.3m/s | <0.3m/s | <0.3m/s | <0.3m/s |
Others |
|
|
|
|
RS232 interface | yes | yes | yes | yes |
Railing | yes | yes | yes | ---- |
Infant bed tilt adjustment | ±10° step less | ±10° step less | ±10° step less | --------- |
Max load of mattress tray | 10kg | 10kg | 10kg | 10kg |
IV Pole Max load | 2kg | 2kg | 2kg | 2kg |